341 research outputs found
Fitting EXAFS data using molecular dynamics outputs and a histogram approach
The estimation of metal nanoparticle diameter by analysis of extended x-ray absorption fine structure (EXAFS) data from coordination numbers is nontrivial, particularly for particles <5 nm in diameter, for which the undercoordination of surface atoms becomes an increasingly significant contribution to the average coordination number. These undercoordinated atoms have increased degrees of freedom over those within the core of the particle, which results in an increase in the degree of structural disorder with decreasing particle size. This increase in disorder, however, is not accounted for by the standard means of EXAFS analysis, where each coordination shell is fitted with a single bond length and disorder term. In addition, the surface atoms of nanoparticles have been observed to undergo a greater contraction than those in the core, further increasing the range of bond distances. Failure to account for this structural change results in an increased disorder being measured, and therefore, a lower apparent coordination number and corresponding particle size are found. Here, we employ molecular dynamics (MD) simulations for a range of nanoparticle sizes to determine each of the nearest neighbor bond lengths, which were then binned into a histogram to construct a radial distribution function (RDF). Each bin from the histogram was considered to be a single scattering path and subsequently used in fitting the EXAFS data obtained for a series of carbon-supported platinum nanoparticles. These MD-based fits are compared with those obtained using a standard fitting model using Artemis and the standard model with the inclusion of higher cumulants, which has previously been used to account for the non-Gaussian distribution of neighboring atoms around the absorber. The results from all three fitting methods were converted to particle sizes and compared with those obtained from transmission electron microscopy (TEM) and x-ray diffraction (XRD) measurements. We find that the use of molecular dynamics simulations resulted in an improved fit over both the standard and cumulant models, in terms of both quality of fit and correlation with the known average particle size
The clinical effectiveness of different parenting programmes for children with conduct problems : a systematic review of randomised controlled trials
Background
Conduct problems are common, disabling and costly. The prognosis for children with conduct problems is poor, with outcomes in adulthood including criminal behaviour, alcoholism, drug abuse, domestic violence, child abuse and a range of psychiatric disorders.
There has been a rapid expansion of group based parent-training programmes for the treatment of children with conduct problems in a number of countries over the past 10 years. Existing reviews of parent training have methodological limitations such as inclusion of non-randomised studies, the absence of investigation for heterogeneity prior to meta-analysis or failure to report confidence intervals.
The objective of the current study was to systematically review randomised controlled trials of parenting programmes for the treatment of children with conduct problems.
Methods
Standard systematic review methods were followed including duplicate inclusion decisions, data extraction and quality assessment. Twenty electronic databases from the fields of medicine, psychology, social science and education were comprehensively searched for RCTs and systematic reviews to February 2006.
Inclusion criteria were: randomised controlled trial; of structured, repeatable parenting programmes; for parents/carers of children up to the age of 18 with a conduct problem; and at least one measure of child behaviour. Meta-analysis and qualitative synthesis were used to summarise included studies.
Results
57 RCTs were included. Studies were small with an average group size of 21. Meta-analyses using both parent (SMD -0.67; 95% CI: -0.91, -0.42) and independent (SMD -0.44; 95% CI: -0.66, -0.23) reports of outcome showed significant differences favouring the intervention group. There was insufficient evidence to determine the relative effectiveness of different approaches to delivering parenting programmes.
Conclusion
Parenting programmes are an effective treatment for children with conduct problems. The relative effectiveness of different parenting programmes requires further research
The acute management of trauma hemorrhage: a systematic review of randomized controlled trials
INTRODUCTION: Worldwide, trauma is a leading cause of death and disability. Haemorrhage is responsible for up to 40% of trauma deaths. Recent strategies to improve mortality rates have focused on optimal methods of early hemorrhage control and correction of coagulopathy. We undertook a systematic review of randomized controlled trials (RCT) which evaluated trauma patients with hemorrhagic shock within the first 24 hours of injury and appraised how the interventions affected three outcomes: bleeding and/or transfusion requirements; correction of trauma induced coagulopathy and mortality. METHODS: Comprehensive searches were performed of MEDLINE, EMBASE, CENTRAL (The Cochrane Library Issue 7, 2010), Current Controlled Trials, ClinicalTrials.gov, the World Health Organization International Clinical Trials Registry Platform (ICTRP) and the National Health Service Blood and Transplant Systematic Review Initiative (NHSBT SRI) RCT Handsearch Database. RESULTS: A total of 35 RCTs were identified which evaluated a wide range of clinical interventions in trauma hemorrhage. Many of the included studies were of low methodological quality and participant numbers were small. Bleeding outcomes were reported in 32 studies; 7 reported significantly reduced transfusion use following a variety of clinical interventions, but this was not accompanied by improved survival. Minimal information was found on traumatic coagulopathy across the identified RCTs. Overall survival was improved in only three RCTs: two small studies and a large study evaluating the use of tranexamic acid. CONCLUSIONS: Despite 35 RCTs there has been little improvement in outcomes over the last few decades. No clear correlation has been demonstrated between transfusion requirements and mortality. The global trauma community should consider a coordinated and strategic approach to conduct well designed studies with pragmatic endpoints
Recommended from our members
¹⁸F-FDG PET for the early diagnosis of Alzheimer's disease dementia and other dementias in people with mild cognitive impairment (MCI).
BACKGROUND: ¹⁸F-FDFG uptake by brain tissue as measured by positron emission tomography (PET) is a well-established method for assessment of brain function in people with dementia. Certain findings on brain PET scans can potentially predict the decline of mild cognitive Impairment (MCI) to Alzheimer's disease dementia or other dementias. OBJECTIVES: To determine the diagnostic accuracy of the ¹⁸F-FDG PET index test for detecting people with MCI at baseline who would clinically convert to Alzheimer's disease dementia or other forms of dementia at follow-up. SEARCH METHODS: We searched the Cochrane Register of Diagnostic Test Accuracy Studies, MEDLINE, EMBASE, Science Citation Index, PsycINFO, BIOSIS previews, LILACS, MEDION, (Meta-analyses van Diagnostisch Onderzoek), DARE (Database of Abstracts of Reviews of Effects), HTA (Health Technology Assessment Database), ARIF (Aggressive Research Intelligence Facility) and C-EBLM (International Federation of Clinical Chemistry and Laboratory Medicine Committee for Evidence-based Laboratory Medicine) databases to January 2013. We checked the reference lists of any relevant studies and systematic reviews for additional studies. SELECTION CRITERIA: We included studies that evaluated the diagnostic accuracy of ¹⁸F-FDG PET to determine the conversion from MCI to Alzheimer's disease dementia or to other forms of dementia, i.e. any or all of vascular dementia, dementia with Lewy bodies, and fronto-temporal dementia. These studies necessarily employ delayed verification of conversion to dementia and are sometimes labelled as 'delayed verification cross-sectional studies'. DATA COLLECTION AND ANALYSIS: Two blinded review authors independently extracted data, resolving disagreement by discussion, with the option to involve a third review author as arbiter if necessary. We extracted and summarised graphically the data for two-by-two tables. We conducted exploratory analyses by plotting estimates of sensitivity and specificity from each study on forest plots and in receiver operating characteristic (ROC) space. When studies had mixed thresholds, we derived estimates of sensitivity and likelihood ratios at fixed values (lower quartile, median and upper quartile) of specificity from the hierarchical summary ROC (HSROC) models. MAIN RESULTS: We included 14 studies (421 participants) in the analysis. The sensitivities for conversion from MCI to Alzheimer's disease dementia were between 25% and 100% while the specificities were between 15% and 100%. From the summary ROC curve we fitted we estimated that the sensitivity was 76% (95% confidence interval (CI): 53.8 to 89.7) at the included study median specificity of 82%. This equates to a positive likelihood ratio of 4.03 (95% CI: 2.97 to 5.47), and a negative likelihood ratio of 0.34 (95% CI: 0.15 to 0.75). Three studies recruited participants from the same Alzheimer's Disease Neuroimaging Initiative (ADNI) cohort but only the largest ADNI study (Herholz 2011) is included in the meta-analysis. In order to demonstrate whether the choice of ADNI study or discriminating brain region (Chételat 2003) or reader assessment (Pardo 2010) make a difference to the pooled estimate, we performed five additional analyses. At the median specificity of 82%, the estimated sensitivity was between 74% and 76%. There was no impact on our findings. In addition to evaluating Alzheimer's disease dementia, five studies evaluated the accuracy of ¹⁸F-FDG PET for all types of dementia. The sensitivities were between 46% and 95% while the specificities were between 29% and 100%; however, we did not conduct a meta-analysis because of too few studies, and those studies which we had found recruited small numbers of participants. Our findings are based on studies with poor reporting, and the majority of included studies had an unclear risk of bias, mainly for the reference standard and participant selection domains. According to the assessment of Index test domain, more than 50% of studies were of poor methodological quality. AUTHORS' CONCLUSIONS: It is difficult to determine to what extent the findings from the meta-analysis can be applied to clinical practice. Given the considerable variability of specificity values and lack of defined thresholds for determination of test positivity in the included studies, the current evidence does not support the routine use of ¹⁸F-FDG PET scans in clinical practice in people with MCI. The ¹⁸F-FDG PET scan is a high-cost investigation, and it is therefore important to clearly demonstrate its accuracy and to standardise the process of ¹⁸F-FDG PET diagnostic modality prior to its being widely used. Future studies with more uniform approaches to thresholds, analysis and study conduct may provide a more homogeneous estimate than the one available from the included studies we have identified
Thromboelastography (TEG) and rotational thromboelastometry (ROTEM) for trauma‑induced coagulopathy in adult trauma patients with bleeding
This review is published as a Cochrane Review in the Cochrane Database of Systematic Reviews 2015, Issue 2. Cochrane Reviews are regularly updated as new evidence emerges and in response to comments and criticisms, and the Cochrane Database of Systematic Reviews should be consulted for the most recent version of the Review.Trauma-induced coagulopathy (TIC) is a disorder of the blood clotting process that occurs soon after trauma injury. A diagnosis of TIC on admission is associated with increased mortality rates, increased burdens of transfusion, greater risks of complications and longer stays in critical care. Current diagnostic testing follows local hospital processes and normally involves conventional coagulation tests including prothrombin time ratio/international normalized ratio (PTr/INR), activated partial prothrombin time and full blood count. In some centres, thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are standard tests, but in the UK they are more commonly used in research settings
The clinical effectiveness and cost-effectiveness of cetuximab (mono- or combination chemotherapy), bevacizumab (combination with non-oxaliplatin chemotherapy) and panitumumab (monotherapy) for the treatment of metastatic colorectal cancer after first-line chemotherapy (review of technology appraisal No.150 and part review of technology appraisal No. 118): a systematic review and economic model
Colorectal cancer is the third most commonly diagnosed cancer in the UK after breast and lung cancer. People with metastatic disease who are sufficiently fit are usually treated with active chemotherapy as first- or second-line therapy. Recently, targeted agents have become available including anti-epidermal growth factor receptor (EGFR) agents, for example cetuximab and panitumumab, and anti-vascular endothelial growth factor (VEGF) receptor agents, for example bevacizumab
A model-based assessment of the cost-utility of strategies to identify Lynch syndrome in early-onset colorectal cancer patients.
This is a freely-available open access publication. Please cite the published version which is available via the DOI link in this record.BACKGROUND: Lynch syndrome is an autosomal dominant cancer predisposition syndrome caused by mutations in the DNA mismatch repair genes MLH1, MSH2, MSH6 and PMS2. Individuals with Lynch syndrome have an increased risk of colorectal cancer, endometrial cancer, ovarian and other cancers. Lynch syndrome remains underdiagnosed in the UK. Reflex testing for Lynch syndrome in early-onset colorectal cancer patients is proposed as a method to identify more families affected by Lynch syndrome and offer surveillance to reduce cancer risks, although cost-effectiveness is viewed as a barrier to implementation. The objective of this project was to estimate the cost-utility of strategies to identify Lynch syndrome in individuals with early-onset colorectal cancer in the NHS. METHODS: A decision analytic model was developed which simulated diagnostic and long-term outcomes over a lifetime horizon for colorectal cancer patients with and without Lynch syndrome and for relatives of those patients. Nine diagnostic strategies were modelled which included microsatellite instability (MSI) testing, immunohistochemistry (IHC), BRAF mutation testing (methylation testing in a scenario analysis), diagnostic mutation testing and Amsterdam II criteria. Biennial colonoscopic surveillance was included for individuals diagnosed with Lynch syndrome and accepting surveillance. Prophylactic hysterectomy with bilateral salpingo-oophorectomy (H-BSO) was similarly included for women diagnosed with Lynch syndrome. Costs from NHS and Personal Social Services perspective and quality-adjusted life years (QALYs) were estimated and discounted at 3.5% per annum. RESULTS: All strategies included for the identification of Lynch syndrome were cost-effective versus no testing. The strategy with the greatest net health benefit was MSI followed by BRAF followed by diagnostic genetic testing, costing £5,491 per QALY gained over no testing. The effect of prophylactic H-BSO on health-related quality of life (HRQoL) is uncertain and could outweigh the health benefits of testing, resulting in overall QALY loss. CONCLUSIONS: Reflex testing for Lynch syndrome in early-onset colorectal cancer patients is predicted to be a cost-effective use of limited financial resources in England and Wales. Research is recommended into the cost-effectiveness of reflex testing for Lynch syndrome in other associated cancers and into the impact of prophylactic H-BSO on HRQoL.NIH
(11)C-PIB-PET for the early diagnosis of Alzheimer's disease dementia and other dementias in people with mild cognitive impairment (MCI).
BACKGROUND: According to the latest revised National Institute of Neurological and Communicative Disorders and Stroke and the Alzheimer's Disease and Related Disorders Association (now known as the Alzheimer's Association) (NINCDS-ADRDA) diagnostic criteria for Alzheimer's disease dementia, the confidence in diagnosing mild cognitive impairment (MCI) due to Alzheimer's disease dementia is raised with the application of imaging biomarkers. These tests, added to core clinical criteria, might increase the sensitivity or specificity of a testing strategy. However, the accuracy of biomarkers in the diagnosis of Alzheimer's disease dementia and other dementias has not yet been systematically evaluated. A formal systematic evaluation of the sensitivity, specificity, and other properties of positron emission tomography (PET) imaging with the (11)C-labelled Pittsburgh Compound-B ((11)C-PIB) ligand was performed. OBJECTIVES: To determine the diagnostic accuracy of the (11)C- PIB-PET scan for detecting participants with MCI at baseline who will clinically convert to Alzheimer's disease dementia or other forms of dementia over a period of time. SEARCH METHODS: The most recent search for this review was performed on 12 January 2013. We searched MEDLINE (OvidSP), EMBASE (OvidSP), BIOSIS Previews (ISI Web of Knowledge), Web of Science and Conference Proceedings (ISI Web of Knowledge), PsycINFO (OvidSP), and LILACS (BIREME). We also requested a search of the Cochrane Register of Diagnostic Test Accuracy Studies (managed by the Cochrane Renal Group).No language or date restrictions were applied to the electronic searches and methodological filters were not used so as to maximise sensitivity. SELECTION CRITERIA: We selected studies that had prospectively defined cohorts with any accepted definition of MCI with baseline (11)C-PIB-PET scan. In addition, we only selected studies that applied a reference standard for Alzheimer's dementia diagnosis for example NINCDS-ADRDA or Diagnostic and Statistical Manual of Mental Disorders-IV (DSM-IV) criteria. DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. The identified full papers were assessed for eligibility and data were extracted to create two by two tables. Two independent assessors performed quality assessment using the QUADAS 2 tool. We used the hierarchical summary receiver operating characteristic (ROC) model to produce a summary ROC curve. MAIN RESULTS: Conversion from MCI to Alzheimer's disease dementia was evaluated in nine studies. The quality of the evidence was limited. Of the 274 participants included in the meta-analysis, 112 developed Alzheimer's dementia. Based on the nine included studies, the median proportion converting was 34%. The studies varied markedly in how the PIB scans were done and interpreted.The sensitivities were between 83% and 100% while the specificities were between 46% and 88%. Because of the variation in thresholds and measures of (11)C-PIB amyloid retention, we did not calculate summary sensitivity and specificity. Although subject to considerable uncertainty, to illustrate the potential strengths and weaknesses of (11)C-PIB-PET scans we estimated from the fitted summary ROC curve that the sensitivity was 96% (95% confidence interval (CI) 87 to 99) at the included study median specificity of 58%. This equated to a positive likelihood ratio of 2.3 and a negative likelihood ratio of 0.07. Assuming a typical conversion rate of MCI to Alzheimer's dementia of 34%, for every 100 PIB scans one person with a negative scan would progress and 28 with a positive scan would not actually progress to Alzheimer's dementia.There were limited data for formal investigation of heterogeneity. We performed two sensitivity analyses to assess the influence of type of reference standard and the use of a pre-specified threshold. There was no effect on our findings. AUTHORS' CONCLUSIONS: Although the good sensitivity achieved in some included studies is promising for the value of (11)C-PIB-PET, given the heterogeneity in the conduct and interpretation of the test and the lack of defined thresholds for determination of test positivity, we cannot recommend its routine use in clinical practice.(11)C-PIB-PET biomarker is a high cost investigation, therefore it is important to clearly demonstrate its accuracy and standardise the process of the (11)C-PIB diagnostic modality prior to it being widely used
- …